What’s meant by the ?change-over? switching function with pressure switches?

A pressure switch with the ?change-over? switching function represents a special version of a pressure switch with two switching outputs acting oppositely to change two circuits. A ?change-over? closes one circuit and simultaneously opens another circuit. Thus a ?change-over? simultaneously fulfils the function of a ?normally open? and also a ?normally closed? contact. This means that, in operation, a ?change-over? can only ever have one connected circuit closed and one energised.
Application examples of pressure switches with ?change-over? switching function
?Change-over? contacts are used to a much lesser extent in industrial applications than the traditional ?normally open? and ?normally closed? variants. However, many applications with simple safety features could be implemented with ?change-over? contacts.
Let?s look at simple machine monitoring, e.g. a coolant unit on a machine tool with visual fault indication (see figure). A pressure switch with a ?change-over? switching function monitors the coolant supply to the tool. If the supply pressure of the coolant is enough, then your switching circuit for a green light is made (green light ?on?). If the pump fails, however, and the supply pressure of the coolant drops off, then your switch changes its switching status. It opens the switching circuit for the green light (green light ?off?) and simultaneously closes the switching circuit for the yellow warning light (yellow light ?on?).Thus the device operator gets a direct visual feedback of any interruption at the coolant supply unit. Naturally, with the correct connection, the ?change-over? could switch other connected loads instead of a warning light, which could, for example, shut the device down or sound a warning hooter.
Use of mechanical versus electronic pressure switches
Through an ever-increasing level of automation, even yet in simple machinery, within the last years there’s been a greater use of mechanical switches with ?normally open? and ?normally closed? as Jail monitoring for the continuous monitoring with sensors. The latest developments in modern electronic switches provide operator, through the simultaneous provision of switching and analogue output signals, a lot better selection of opportunities in the look of safety control. Thus, a control with the help of electronic switches can ? through the analogue signal ? continuously monitor system pressure, temperature or level, while also, as well ? through the evaluation of the switch contacts ? fulfilling an independent safety function through the monitoring of critical states, whereby hazards to personnel and machinery could be prevented.
Apart from ?change-over?, manufacturers of switches provide a selection of switching functions for all applications, such as ?normally closed? or ?normally open?. With Unhurried of these switching functions, operators can fulfil almost 100 % of all simple control and safety tasks within machine building.
Note
More info on mechanical pressure switches and electronic pressure switches are available on the WIKA website. In the event you need any suggestions about the selection of the right switch, your contact will gladly assist you to.
Also read our article
What’s meant by the ?normally open? switching function with pressure switches?

Leave a Comment