Very tall buildings have unique fireplace security design points that aren’t skilled in different kinds of structures. For instance, because the peak of the construction is past the attain of ladders, tall buildings are equipped with more fireplace security options as it is not potential for the fire department to provoke exterior rescues from ladders and suppress fires with outdoors hose streams.
In regards to fireside safety, the efficiency historical past of very tall buildings while very profitable, has not been with out catastrophic incidents. Many of these incidents have resulted in 1) quite a few deaths and accidents, 2) excessive property loss and 3) disruptions in enterprise continuity. For example, the One Meridian Plaza high-rise fire in Philadelphia that occurred in 1991 resulted within the loss of three firefighters and constructing by no means being re-opened. In 1988, the fire in the Interstate Bank Building in Los Angeles skilled one fatality and resulted within the building being out of use for six months.
Based on research and lessons realized, the mannequin building codes have made vital progress in addressing fireplace questions of safety in very tall buildings. At the identical time, the complexity and unique challenges of today’s very tall buildings have created an surroundings where comprehensive performance-based solutions have turn out to be a necessity.
To assist the design neighborhood with developing performance-based fire security solutions for very tall buildings, in 2013, the Society of Fire Protection Engineers (SFPE) partnered with the International Code Council (ICC) to develop the Engineering Guide: Fire Safety in Very Tall Buildings.1 This publication is written as a guide for use along side local codes and requirements and serves as an added device to those concerned within the hearth protection design of distinctive tall buildings. The guide focuses on design issues that affect the fire safety efficiency of tall buildings and how engineers can incorporate performance-based fireplace protection via hazard and danger evaluation methodologies into the design of tall buildings. This article will talk about a variety of the unique fireplace safety design strategies/methodologies employed in the design of tall buildings which are referenced within the ICC/SFPE Guide.
Emergency Egress
Developing an efficient evacuation technique for a tall constructing is challenging because the time to complete a full building evacuation increases with constructing peak. At the same time, above certain heights, the standard method of requiring all occupants to simultaneous evacuate will not be sensible as occupants become extra vulnerable to further dangers when evacuating through stairways. That is why tall buildings often make use of non-traditional or various evacuation strategies.
When designing an egress plan for a tall building, the first aim ought to be to supply an acceptable means to allow occupants to move to a spot of security. To accomplish this goal, there are several evacuation methodologies that are obtainable to the design staff. These evacuation methods can embody however are not restricted to 1) defend-in-place, 2) transferring individuals to areas of refuge and 3) phased/progressive evacuation. It can be possible that a combination of those methods could be this best solution. When deciding on an appropriate strategy, the design group should contemplate the required degree of security for the building occupants and the constructing performance goals which are recognized by the building’s stakeholders.
Using protected elevators has become another evacuation technique that is becoming more prevalent in the design of tall buildings. In addition to aiding the fire division with operations and rescues, protected elevators are actually getting used for constructing evacuation, significantly for occupants with disabilities. When considering elevators in an evacuation strategy, there are a selection of design issues to consider: 1) security and reliability of the elevators, 2) coordination of elevator controls and constructing safety methods, 3) education of building occupants and first responders and 4) communication to constructing occupants in the course of the emergency.
Tall buildings usually make use of non-traditional or alternative evacuation methods.
Fire Resistance
The consequences of partial or world collapse of tall buildings as a end result of a severe fire pose a big danger to numerous individuals, the fire service and surrounding buildings. At the same time, tall buildings typically have distinctive design features whose role within the structure and fireplace response are not easily understood utilizing traditional fire safety strategies. These distinctive components might warrant a need to adopt a complicated structural fireplace engineering evaluation to demonstrate that the building’s efficiency aims are met.
Performance-based design of structural fire resistance entails three steps: (1) determination of the thermal boundary circumstances to a construction ensuing from a fire; (2) calculation of the thermal response of the construction to the fireplace exposure, and (3) dedication of the structural response of the construction. Guidance on performing this kind of analysis could be found in the SFPE Engineering Standard on Calculating Fire Exposures to Structures2, and SFPE Engineering Standard on Calculation Methods to Predict the Thermal Performance of Structural and Fire Resistive Assemblies.three
Water-Based Fire Suppression Systems
In tall buildings, the water supply required for fire safety methods can be greater than the potential of the public water supply. As such, fire safety system water provides for sprinkler methods and standpipes require the use of pumps and/or gravity water tanks to spice up the water strain. Reliability of this water supply is a key consideration. As such, redundant hearth pumps, gravity-based storage supplies, or both could also be wanted to reinforce system reliability.
Another issue to consider when designing water-based fireplace suppression techniques is pressure control as it is potential for system elements to be uncovered to pressures that exceed its maximum working stress. Consequently, it might be necessary to design vertical strain zones to regulate pressures within the zone. Additionally, strain regulating valves are often needed. When installed, care must be taken to guarantee that these strain regulating valves are installed correctly and adequately maintained.
Fire Alarm and Communication Systems
Providing building occupants with accurate information during emergencies will increase their capability to make applicable choices about their own security. Fire alarm and communication methods are an important supply of this information. Very tall buildings employ voice communication techniques that are integrated into the fireplace alarm system. When designing voice communication techniques you will need to make positive that the system supplies reliable and credible info.
Fire alarm system survivability is one other import issue to contemplate in fireplace alarm system design. For tall buildings, consideration ought to be given in order that an attack by a fireplace in an evacuation zone does not impair the voice messaging outdoors the zone. Some of the design issues to attain survivability might embody: 1) protection of management tools from fireplace, 2) protection of circuits. 3) configuration of circuits and 4) shielding of panels.
Tall buildings typically employ smoke control systems that both vent, exhaust or limit the unfold of smoke.
Smoke Control
Controlling the unfold of smoke is extra sophisticated in tall buildings. For example, tall buildings expertise a phenomenon referred to as stack effect. Stack effect occurs when a tall building experiences a stress distinction all through its peak as a result of temperature differentials between the outside air temperature and the within constructing temperature. This causes air to move vertically, relying on the surface air temperature – both upward or downward in a building. It also can trigger smoke from a constructing fire to unfold all through the building if not managed. That is why tall buildings often make use of smoke management methods that both vent, exhaust or restrict the spread of smoke.
Other considerations in tall buildings included the air movement created by the piston effect of elevators and the effects of wind. Air motion caused by elevator cars ascending and descending in a shaft and the results of wind can lead to smoke movement in tall buildings. These impacts turn into more pronounced as the peak of the constructing enhance.
Because very tall buildings complicate smoke spread, efficient smoke control is harder to achieve. The possible options are numerous and embody a combination of energetic and passive features similar to however not limited to: 1) smoke barrier partitions and floors, 2) stairway pressurization systems, 3) pressurized zoned smoke control offered by the air-handling tools, and 4) smoke dampers. เครื่องมือที่ใช้วัดความดัน implemented into the design needs to handle the constructing itself, its uses, related occupant traits and reliability.
First Service Issues
It goes with out saying that tall buildings present distinctive challenges to the fireplace service. During the planning and design phases, it’s important for the design staff to work with the fireplace service to discuss the sort of sources which may be wanted for an incident and the actions that shall be needed to mitigate an incident. This consists of developing building and post-construction preplans. These preplans should include and not be limited to creating provisions for 1) fireplace service access together with transport to the best degree of the building, 2) establishing a water provide, 3) standpipe systems (temporary and permanent), 4) communication techniques, and 5) understanding the operations of the hearth safety systems within the building.
One of the challenges the fireplace service faces during incidents in tall buildings is the power of firefighters to move equipment to the incident location. Designers should take into account how the fire service can transport its tools from the response level to the highest level in a secure manner.
Additionally, care needs to be taken when designing the fireplace command center as it’ll present the fireplace service command workers with important information about the incident. The fireplace command middle needs to be accessible and should embrace 1) controls for building methods, 2) contact info for constructing management, 3) current buildings plans, 4) emergency response and egress plans and 5) preplans.
1 International Code Council/SFPE. (2013). Engineering Guide: Fire Safety for Very Tall Buildings. Country Club Hills, IL.
2 SFPE. (2011). SFPE Standard S.01 2011, Engineering Standards on Calculating Fire Exposures to Structures. Gaithersburg, Maryland.
3 SFPE. 2015). SFPE Standard S.02 2015, SFPE Engineering Standard on Calculation Methods to Predict the Thermal Performance of Structural and Fire Resistive Assemblies. Gaithersburg, Maryland.
Share